  • SQP41-1(1).png
  • SQP41-2(1).png
  • SQP41-3(1).png

SQP41 Low-Noise Vane Pump

Key words:Hydraulic tools

E-mail:

Details

Specification

 

Series

Displacement code of the shaft-end pump

Displacement code of the cover-end pump

SQP41

42、 45、 50、 57、 60、 66、 75

2、 3、 4、 5、 6、 7、 8、 9、 10、 11、 12、 14

 

 

Model code

 

Img

 

 

Installation and Use

 

1. During installation, the concentricity tolerance between the pump shaft and the motor must be less than 0.10 mm (TIR), and the maximum allowable angular error must be less than 0.2 degrees. Use a flexible coupling; the pump shaft must not bear radial and axial loads; the bracket must be sturdy, rigid, and able to fully absorb vibrations.
2. Secure the pipeline according to the diameter, especially the inlet pipe, and install a safety relief valve in the system (the inlet flow rate is between 0.5 and 1.5 m/s). The set pressure of the safety valve must not exceed the maximum pressure of the pump; the inlet pipe must be strictly sealed and must not leak; the oil tank should be equipped with a diaphragm to separate bubbles and dirt from the oil; the oil return nozzle should be below the liquid level, with a minimum depth of 50 mm, even at low positions, to avoid bubble formation.
3. Set the suction pressure at the pump inlet: Hydraulic oil for hydraulic oil is +35~ -16.7 KPa. Hydraulic oil for water-ethylene glycol and phosphate esters is +35~ -10.1 KPa.
4. If the pump is installed on the oil tank or above the oil tank cover, the suction height of the pump should be less than 500 mm.
5. The oil should be kept clean, and the pipelines and oil tank must be thoroughly cleaned; a precision filter should be assembled in the system, with a recommended accuracy of 25 μm, and the oil cleanliness should be within NSA12. Install a filter with sufficient capacity (the rated flow rate should be more than twice the pump flow rate) 50 mm from the pump inlet, with a recommended accuracy of 100 μm (150 mesh).
6. It is recommended to use anti-wear industrial hydraulic oil or automotive crankcase oil with the letter designation SC, SD, SE, or SF, with a viscosity grade of 32 to 68 cSt at 40 ℃.
Preferred viscosity at rated speed and pressure:
Minimum 13 cSt Maximum 54 cSt
Minimum 49 ℃ Maximum 65 ℃
7. Check the inlet, outlet, and rotation direction before starting the pump. After fixing the pump, manually rotate the pump shaft evenly and flexibly. It is best to fill the pump with oil before the first use.
During initial operation or operation after a long rest, the pump may have difficulty sucking in liquid; in this case, an air release valve should be installed on the discharge side in advance, or the air should be discharged by slightly loosening the connection on the discharge side. During startup, try to operate the pump intermittently without load.
8. Do not start the pump when the outlet pressure is lower than the inlet pressure. This will cause operating noise and blade instability.
9. At startup, if the oil viscosity is higher than the suitable viscosity (54 cSt), the pressure should be limited to 50% or less of the respective rated value until the system heats up.

 

Installation Connection Dimensions

 

 

◎Key Shaft

 

Model

Shaft Cooling

A

B

C

D

E

F Key
Width × Length

SQP41

1

62

12.7

14.2

31.75/31.70

35.25/35.10

7.94 × 28.5

86

87.4

12.7

14.2

38.075/38.05

42.4/42.25

9.54 × 50.8

 

◎Spline Shaft

 

Model

Shaft Cooling

A

B

C

D

E

Spline Data

Number of Teeth
Number of Teeth

Pitch

Major Diameter
Minor Diameter

Root
Minor Diameter

Fit
12/24

SQP41

11

61.9

12.7

14.3

9.7

39.6

14

31.7/31.67

26.99/26.64

Major Diameter Fit

Large
diameter fit

Get Quote

Welcome to leave a message, there may be a discount

Note: Please leave your contact information and our professionals will contact you as soon as possible!